SUP-MPP500 Economy Multi-parameter Water Analyzer

The multi-parameter water quality analyzer is a versatile solution, ideal for urban and rural water supply facilities, tap water distribution networks, secondary water supply systems, household taps, indoor swimming pools, and real-time water quality monitoring, including large-scale purification units and direct drinking water systems. This essential online analytical tool supports critical applications in water plant production management, water resource conservation, and public health oversight, ensuring precision and reliability across diverse environments.

Characteristics

Integrated design: Integration configuration avoids flooding and ground moisture, and no space is occupied.

Multiple parameters monitoring: Offer multiple monitoring for turbidity, residual chlorine dioxide, pH, temperature, conductivity, TDS, dissolved oxygen, and ORP.

High precision:  Long-term stable and accurate measurement in the order of tap water (0.1~1NTU) and purified water (0.001~0.1NTU).

Low maintenance: Provide remote control, like automatic sewage discharge and adjustment.

Equipment protection: Support built-in ingress detection to guard against damage by sudden device failure or breakdown.

Smart communication: standard RS485 Modbus-RTU protocol and device wireless data transmission channel.

PH /ORP: 0-14pH, ±2000mV

Turbidity: 0-1NTU / 0-20NTU / 0-100NTU / 0-2000NTU

Conductivity: 0-20000uS/cm / 0~20mS/m

Residual chlorine/chlorine dioxide/ozone: 0-5mg/L / 0-20mg/L

Temperature: 0℃ - 50℃

  • Introduction

The multi-parameter water quality analyzer represents a cutting-edge advancement in water monitoring technology, proudly crafted and distributed by Supmea Automation. This reliable instrument excels in remote water quality assessment across urban and rural treatment facilities, water transmission pipelines, secondary supply networks, end-user points, indoor swimming pools, extensive purification processes, and direct drinking water systems. It serves as a vital online analytical tool, supporting key areas such as water plant operational oversight, water resource management, and health compliance monitoring.

Designed with flexibility in mind, this water quality monitor is available in both standard and tailored versions. The standard model effectively tracks parameters including turbidity, residual chlorine/chlorine dioxide/ozone, pH, temperature, conductivity/TDS, and ORP. The custom version extends this capability with premium options, including parameter removal, personalized design elements such as logos and system names, and other bespoke features tailored to client specifications.

SUP-MPP500 Economy Multi-parameter Water Analyzer

  • Specification

Item Index Value
System Power supply (220±22)VAC, (50±1)Hz
Power consumption ≤30W
Cabinet size 500mm*400mm*200mm
Weight about 12Kg
Storage temperature 4℃~+50℃
Operating temperature 0℃~+50℃
Working humidity ≤95%RH (no condensation)
Inlet water flow 0.03~0.06m³/h
Inlet pressure < 0.3MPa
Display Color Touch Screen
Communication interface RS-485 Modbus RTU communication protocol + wireless interface
Turbidity Range 0-1NTU / 0-20NTU / 0-100NTU / 0-2000NTU
Resolution 0-1NTU / 0-20NTU / 0-100NTU:0.001NTU   0-2000NTU:0.01NTU
Detection limit 0.005 NTU
Zero drift ≤1.5%
Indication stability ≤1.5%
Accuracy 2% or ±0.02NTU; 10% or 0.5NTU (0-2000NTU)
Repeatability ≤1%
Response time T90≤120s
Recommended maintenance period 3-12 months (depending on the water quality on site)
Residual chlorine/chlorine dioxide/ozone Range 0-5mg/L / 0-20mg/L
Resolution 0.01mg/L
Detection limit 0.05mg/L
Accuracy ±0.05mg/L or ±5% (DPD comparison error ±10%)
Response time ≤120 seconds
Recommended maintenance period 1-3 months or weekly calibration, 3-6 months to replace consumables
pH /ORP(optional) Range 0-14 pH, ±2000 mV (ORP)
Resolution 0.01 pH, ±1 mV (ORP)
Accuracy ±0.1 pH, ±20 mV (ORP) or ±2%
Repeatability ±0.1 pH, ±10 mV (ORP)
Response time ≤60 seconds
Recommended maintenance period 1-3 months
Temperature Range 0℃ - 50℃
Resolution 0.1℃
Accuracy ±0.5℃
Repeatability ≤0.5℃
Response time ≤25 seconds
Recommended maintenance period 12 months
Conductivity (Optional) Range 0-20000uS/cm;  0-20uS/cm(Pure water sensor)
Accuracy ±0.8%F.S; ±3%F.S(Pure water sensor)
Resolution 0.01uS/cm
Repeatability ≤0.4%FS
Response time ≤30 seconds
Recommended maintenance period 3-6 months

SUP-MPP500 Economy Multi-parameter Water Analyzer

SUP-MPP500 Economy Multi-parameter Water AnalyzerSUP-MPP500 Economy Multi-parameter Water Analyzer
 

SUP-MPP500 Economy Multi-parameter Water Analyzer

SUP-MPP500 Economy Multi-parameter Water Analyzer

SUP-MPP500 Economy Multi-parameter Water AnalyzerSUP-MPP500 Economy Multi-parameter Water AnalyzerSUP-MPP500 Economy Multi-parameter Water Analyzer

Need more information?

Contact us for more details about our boilers,solutions and services

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.