Product |
Guided wave radar level meter |
Model |
SUP-RD701 |
Accuracy |
± 5mm |
Application |
Media with layered properties such as oil and water |
Process connection |
Thread/ Flange(optional) |
Process temperature |
(-40~250)℃ |
Process pressure |
-0.1 ~ 4MPa |
Ingress protection |
IP67 |
Frequency range |
500MHz-1.8GHz |
Signal output |
4-20mA/HART |
RS485/Modbus |
Power supply |
24VDC/ Two-wire
(24VDC/220VAC)/ Four-wire |



H----Measuring range
L----Empty tank height
B----Blind area
E----Minimum distance from probe to tank wall >50mm
Note:
The top Blind area refers to the minimum distance between the highest material surface of the material and the measurement reference point.
Blind area at the bottom refers to a distance that cannot be accurately measured near the bottom of the cable.
The effective measurement distance is between the top Blind area and the bottom Blind area.