FMC240 Electronic Water Meter for flow measurement

Introduction The FMC240 electronic water meter is an ideal solution for measuring the flow of tap water. This type of flow meter uses Faraday's law of electromagnetic induction to measure the flow

Characteristics

Accuracy: Class 2(Please see datasheet for details)

Theoretical value: Water: Min. 20μS/cm; Other liquid: Min. 5μS/cm
Recommended value: >30μS/cm

Strong anti-interference ability, under normal grounding conditions, the flow value can be displayed stably

With lightning protection capability, it can be used in lightning-prone areas

  • Introduction

The FMC240 Supmea's electronic water meter does not contain any moving parts, rotating gears or turbines, or bearings. Instead, it relies on two electrodes to measure the density of the induced magnetic field that results from an electrically conductive fluid, such as water, flowing through a pipe. So there is no susceptibility to bearing wear or other mechanical wear-and-tear issues.

As for the electrodes and the liner used in electronic water meter, these components can be fabricated from a variety of materials to make the meter compatible with different conditions of water.

The only limitation of the electronic water meter is that the measured fluid media must be electrically conductive (>5μS/cm). Non-conductive fluids, such as oil and other petroleum-based fluids, cannot be measured with the technology.

 

Electromagnetic Flowmeter for Tap Water 

  • Specification

 Product  Electronic water meter
 Model  FMC240 
 Diameter nominal  DN15~DN1000
 Nominal pressure DN15 - DN250, PN ≤1.6MPa
DN300 - DN1000, PN ≤1.0MPa
 Accuracy
Class 2(Please see datasheet for details)
 Repetitiveness 0.16%
 Liner material Neoprene (CR), Polyurethane (PU), PTFE (F4), PFEP (F46), PFA
 Electrode material 316L Stainless Steel, Hastelloy C, Hastelloy B, Ti, Ta, Pt
 Medium temperature Neoprene: -10…+70℃ Polyurethane: -10…+60℃ PTFE/FEP: -10…+120℃ PFA: -10…+120℃
 Power supply 220VAC, 24VDC
 Structure type  Compact type, Remote type
 Ingress protection  IP65, IP68(remote type only)
 Product standard  JB/T 9248-2015

 

  • Measuring principle

Mag meter works based on Faraday's law, when the liquid goes through the pipe at the flow rate of v with a diameter D, within which a magnetic flux density of B is created by an exciting coil, the following electromotive E is generated in proportion to flow speed v:

E=K×B×V×D

Where:
E-Induced electromotive force 
K-Meter constant 
B-Magnetic induction density
V-Average flow speed in cross-section of measuring tube 
D-Inner diameter of measuring tube   


flowmeter principle


                 

  • Calibration Line

magnetic flowmeter calibration

mt flowmeter calibrate

electromagnetic flowmeter factory

 

success story

electromagnetic flowmeter manufacturer

mag flowmeter application

FMC240 Electronic Water Meter for flow measurement

Need more information?

Contact us for more details about our boilers,solutions and services

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.