Electromagnetic flowmeter is only applicable to measure the flow of conductive liquid, which is wide used in water supply, sewage water measuring, industry chemical measuring etc. The remote type is with high IP protection class and can be installed in different locations for the transmitter and converter. Output signal can pulse,4-20mA or with RS485 communication.
Accuracy: ±0.5%(Flow speed > 1m/s)
Reliably: 0.15%
Theoretical value: Water: Min. 20μS/cm; Other liquid: Min. 5μS/cm
Recommended value: >30μS/cm
Flange: ANSI/JIS/DIN DN15…1000
Ingress protection: IP65
Specification
Product | Sanitary type electromagnetic flowmeter |
Model | SUP-LDGS |
Diameter nominal | DN15~DN100 |
Nominal pressure | 0.6~4.0MPa |
Accuracy | ±0.5%,±2mm/s(flowrate<1m/s) |
Repetitiveness | 0.2% |
Liner material | PFA, F46, Neoprene, PTFE, FEP |
Electrode material | Stainless steel SUS316L, Hastelloy C, Titanium, |
Tantalum, Platinum-iridium | |
Medium temperature | Integral type: -10℃~80℃ |
Split type: -25℃~180℃ | |
Ambient temperature | -10℃~55℃ |
Power supply | 100-240VAC,50/60Hz / 22VDC—26VDC |
Electrical conductivity | Water 20μS/cm other medium 5μS/cm |
Ingress protection | IP65, IP68(optional) |
Product standard | JB/T 9248-2015 |
Measuring principle
Mag meter works based on Faraday's law, and measure conductive medium with conductivity more than 5 μs/cm and flow range from 0.2 to 15 m/s. An Electromagnetic Flowmeter is a volumetric Flowmeter that measures the flow velocity of a liquid through a pipe.
The measurement principle of magnetic flowmeters can be described as follows: when the liquid goes through the pipe at the flow rate of v with a diameter D, within which a magnetic flux density of B is created by an exciting coil, the following electromotive E is generated in proportion to flow speed v:
E=K×B×V×D
Where: E-Induced electromotive force K-Meter constant B-Magnetic induction density V-Average flow speed in cross-section of measuring tube D-Inner diameter of measuring tube |
![]() |
Introduction
SUP-LDGS sanitary electromagnetic flowmeter is applicable for all food grade conductive liquids measure, such as drinking water, food processing, pharmaceutical industry and many others. Typical applications are monitoring accurate measurements in liquid, metering and custody transfer.
Noted: the product strictly prohibited to be used in explosion-proof occasions.
Application
Electromagnetic flowmeters have been used throughout industries for more than 60 years. These meters are applicable for all conductive liquids, such as: Domestic water, industrial water, raw water, ground water, urban sewage, industrial wastewater, the processed neutral pulp, pulp slurry, etc
Automatic calibration line
Stability test